EEG Simplified

  • Convenient for the Operator

    Easy to put on and adjust. Average prep time: 5 minutes. No wires. No glue. No clean up.

  • Comfortable for the Patient

    No residue, soft tip electrodes, soft support pads, gentle on the skin.

Innovation Highlights

ACTIVE ELECTRODE TECHNOLOGY 10-20 POSITIONING
SOFT SUPPORT PADS NOISE SHEILDING
DYNAMIC NOISE CANCELLATION HIGH RESOLUTION DIGITAL SIGNAL
FEELS LIKE A BIKE HELMET SPRING LOADED PLUNGER
HEAD SIZE ADJUSTMENT - BAND DIALS SOFT, FLEX ELECTRODES
Zeto Dry Electrode EEG Device Components
Zeto EEG Monitoring Device Suitcase Close
Zeto EEG Monitoring Device Box Suitcase Open
Number of electrodes 19
Reference electrodes A1/A2 or built-in choices
Channel Positions 10-20 system compliant
Weight < 650g or 23oz
Battery Rechargeable Li-ion
Run time 5-6 hours continuous
Bandwidth 0.003 – 250Hz
Sampling Rate 500Hz
Analog to Digital Converter 24 bits
Common Mode Rejection Ratio > 120 dB
Input Impedance 1 TΩ
Noise (1-50Hz) < 1μV RMS
Wireless Mode WiFi
Range 10m (direct line of sight)
Video Multi camera feed, HD video (USB, IP enabled)
ECG Single Differential
Photic Sensor Wireless, Built-in
Accelerometer 3 axis + Gyroscope
Triggers IR, TTL

Software User Application

All interactions are performed through the Zeto app or an HTML5 capable web browser such as Google Chrome

  • Montage Selection
  • Gain
  • Time Scale
  • Filter Setting
  • Contact Quality
  • Video
  • Web-based access
  • EEG Study manager
  • Video Review
  • Annotation features
  • Intuitive Navigation
  • Time-Frequency Analysis
  • Report Generator
  • Analytics
  • Automated software upgrades
Zeto Brain Wave Monitoring Device Cloud Platform
  • Montage Selection
  • Gain
  • Time Scale
  • Filter Setting
  • Contact Quality
  • Video

Video Tutorials

Setting up the headset demo

Software demo for recording EEG

Software demo for reading EEG

Zeto Dry EEG Headset

How does Zeto’s signal quality compare to that of traditional EEG?

Zeto is obsessed with signal quality. It turned out to be a much harder problem than initially expected, but Zeto solved it through a combination of proprietary electrode materials and innovative electrical techniques. The Active Electrode Technology (AET) and Dynamic Noise Cancellation (DNC) ensure that the bio-potential is precisely transmitted the AET pre-amplifies and conditions the signal at the source and the DNC removes noise in real-time.

Zeto performed 3 clinical studies across 50 subjects that showed signal quality is on par with FDA-cleared traditional EEG systems. The studies involved simultaneous recordings on subjects with Zeto EEG (zEEG) and Clinical EEG (cEEG) electrodes placed about 1-2 cm from each other. For sample results, see below.

Zeto is happy to answer any questions.

To experience the Zeto system for yourself, visit us at conferences, or to schedule an online demo, contact a sales representative here.

Signal Quality